Product Overview

The LP-YLW5 green PMMA acrylic laser safety window is designed for observation panels in laser equipment enclosures. The manufacturer specifies filtering bands of 200–450nm and 900–1700nm, including OD >7 at 1030–1400nm for applications involving 1064nm lasers.

With a specified light transmittance of 22%, this panel allows observation through the enclosure while attenuating radiation within the listed wavelength bands. The manufacturer identifies 1060–1090nm fiber laser systems as a target application.

Technical Specifications

Parameter Specification
Model LP-YLW5
Material PMMA acrylic
Color Green
Specified Filtering Bands 200–450nm and 900–1700nm
Target Fiber Laser Wavelengths 1060–1090nm
Light Transmittance 22%
Panel Size 200 × 250mm
Thickness 5mm

Optical Density Ratings

Values below are stated in the datasheet.

Wavelength Range Optical Density
200–450nm OD >5
900–1030nm OD >6
1030–1400nm OD >7
1400–1700nm OD >6

Manufacturer-Listed AB Values

Wavelength Range AB Value
316–450nm D I R AB5
900–1030nm D AB6 + I AB6
1030–1400nm D AB4 + I AB8 + R AB8
1400–1700nm D AB2 + I AB3

Applications

  • Fiber laser equipment enclosure viewing panels.
  • Laser marking machine observation windows.
  • Laser engraving machine viewing panels.
  • Laser cutting machine observation windows.

Custom Sizes

The listed price is for one 200 × 250 × 5mm panel. For other dimensions, please contact us to confirm availability, specifications, and pricing.

Package Includes

1 × LP-YLW5 PMMA Acrylic Laser Safety Window

Selection Notice: Suitability depends on laser wavelength, output, operating mode, exposure conditions, and enclosure design. Optical density alone does not establish suitability for every application. Confirm the required protection level, applicable test documentation, and installation requirements before use.

View full details